<11006749 001>
Page 21 of 50
IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
17.6 Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No stranded conductors
connected to screw terminals.
N
17.7 Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
No cover fixing devices.
N
17.8 Fixing devices for detachable legs or stands
provided
No detachable legs or stands.
N
17.9 Internal pluggable connections, affecting safety,
unlikely to become disconnected
Internal pluggable connections
have mechanical securing.
P
18 MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965: No picture tube provided.
N
Picture tube separately approved to 18.1 ................
N
18.1 Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
N
18.2 Intrinsically protected tubes: tests on 12 samples
N
18.2.1 Samples subject to ageing: 6
N
18.2.2 Samples subject to implosion test: 6
N
18.2.3 Samples subject to mechanical strength test (steel
ball): 6
N
18.3 Non-intrinsically protected tubes tested to 18.3
N
19 STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ................. :
Mass of equipment: 15.5 kg
P
Apparatus intended to be fastened in place –
suitable instructions
Apparatus is not intended to be
fastended in place.
N
19.1 Test on a plane, inclined at 10
o
to the horizontal Complied.
As client’s requirement, the
equipment was placed on a
glass surface and tilt 10
°
. No
overbalance during the test.
P
19.2 100 N force applied vertically downwards Ditto.
P
19.3 Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
N
Comments to this Manuals