<11006749 001>
Page 19 of 50
IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8 Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9 Termination of non-detachable cords: wires
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
N
15.4 Devices forming a part of the mains plug Appliance inlet used. No power
cord supplied.
N
15.4.1 No undue strain on mains socket-outlets
N
15.4.2 Device complies with standard for dimensions of
mains plugs
N
15.4.3 Device has adequate mechanical strength (tests
a,b,c)
N
16 EXTERNAL FLEXIBLE CORDS
N
16.1 Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Power supply cord is not
provided.
N
Non-detachable cords for Class I have
green/yellow core for protective earth
Apparatus intended for use
with detachable power cord.
N
16.2 Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
No power supply cord
provided.
N
16.3 a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of
IEC 60227-2)
N
16.4 Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
Comments to this Manuals