<11006749 001>
Page 13 of 50
IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict
13.6 Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
No such components.
N
Conductive parts along reliably cemented joints
comply with 8.8
Ditto.
N
13.7 Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
Not such a construction.
N
13.8 Parts filled with insulating compound, meeting the
requirements of 8.8
Photo couplers used in SPS
are approved components.
P
14 COMPONENTS
P
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
No such resistors used.
N
b) Resistors, other than between hazardous live
parts and accessible parts
Ditto.
N
b) Resistors separately approved ........................... :
Ditto.
N
14.2 Capacitors and RC units In approved SPS.
P
Capacitors separately approved Yes.
P
14.2.1 Y capacitors tested to IEC 60384-14, 2
nd
edition ... :
The subclass Y2 capacitors
which used between hazardous
live and PE were approved
according to IEC 60384-
14:1993. In approved SPS.
P
14.2.2 X capacitors tested to IEC 60384-14, 2
nd
edition ... :
The X capacitors which
conductively connected
between the mains were
approved according to IEC
60384-14:1993. In approved
SPS.
P
14.2.3 Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
No such capacitors used.
N
14.2.5 Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
In approved SPS.
P
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Ditto.
P