Page view 12
<11006749 001>
Page 9 of 50
IEC/EN 60065
Clause RequirementTest Result - Remark Verdict
No undue reduction of creepages or clearance
distances if wires become detached
Conductors with mechanical
securing and quick connection.
P
Vibration test carried out ......................................... :
See 12.1.2.
P
8.12 Adequate cross-sectional area of internal wiring to
mains socket-outlets
No mains socket outlet.
N
8.13 Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
No windows, lenses, lamp
covers etc.
N
8.14 Adequate fastening of covers (pull test 50 N for
10 s)
Secured by screws.
P
8.15 No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
The internal wiring does not
touch hot parts or sharp edges
that may damage its insulation
and cause hazard.
P
8.16 Only special supply equipment can be used Supply from mains only.
N
8.17 Insulated winding wire without additional
interleaved insulation
In approved SPS.
P
8.18 Endurance test as required by 8.17
N
8.19 Disconnection from the mains See below.
P
8.19.1 Disconnect device Appliance inlet used.
P
All-pole switch or circuit breaker with >3mm contact
separation
Ditto.
N
8.19.2 Mains switch ON indication Compliance in approved SPS.
P
8.20 Switch not fitted in the mains cord
P
8.21 Bridging components comply with clause 14
N
9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1 Testing on the outside
P
9.1.1 For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
See 9.1.1.2.
P
9.1.1.1 Touch current measured from terminal devices
using the network in annex D ................................. :
The touch current was
measured at output
connectors, inverter output
connectors and plastic
enclosure were conducted with
the results in appended table
9.1.1.
The measuring network
according to annex D.
P
Discharge not exceeding 45 µC Less than 45 µC.
P
Page view 12