Acer V173 Technical Information Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
- 14 -
Notes 5) Definition of Luminance of White : measure the luminance of white at center point.
Notes 6)Definition of 5 points brightness uniformity (Measuring points: Refer to the Note 5)
Bmax
B
UNI
= ⎯⎯⎯⎯⎯⎯⎯
Bmin
Bmax: Maximum brightness
Bmin: Minimum brightness
Notes 7) Definition of Flicker level
Flicker Voltage
pp
F = ⎯⎯⎯⎯⎯⎯⎯⎯⎯ x 100 %
LMD Voltage
dc
One maximum value of three estimated values.
For this test ,an LMD(Light Measurement Device)is needed with adequate response time to track any
visible rate flicker component and with a voltage level output proportional
To luminance intensity.
Test Pattern: For dot inversion Driving(Gray levels of foreground dots on the test panel
Are G22,G32,and G45)
Test Point :Center point of the display area
Page view 13