Acer Altos S700F User Manual

Browse online or download User Manual for Unknown Acer Altos S700F. Acer Altos S700F User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 124
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - Altos S700 Series

Altos S700 SeriesUser’s Guide

Page 2

xImportant safety informationOnly a technically qualified person shall access, integrate, configure, and service this product.Intended application use

Page 3 - Contents

Appendix A Safety Statement Translations84 Hvis der i mere end ét udstyrsrackkabinet er indbyrdes forbundet udstyr, bør disse kabinetter have samme gr

Page 4 - Contentsiv

85 Før det blir gjort forsøk på installere eller fjerne komponenter, må det tas forholdsregler for å avverge statisk elektrisitet. Minimumskravet er r

Page 5

Appendix A Safety Statement Translations86 Når hylle for rackmontering blir installert eller fjernet, må alle strømforsyninger og diskstasjoner fjerne

Page 6 - Contentsvi

87 Nach dem Entfernen des LS Module muss die entstehende Lücke durch eine Blende oder durch die Installation eines anderen LS Module geschlossen werde

Page 7 - Audience

Appendix A Safety Statement Translations88WarningA possible shock hazard may exist in the area of the fan connection. Im Bereich des Lüftungsanschluss

Page 8 - FCC notice

Appendix BTechnical Specifications

Page 9 - Notice: Canadian users

Appendix B Technical Specifications90Technical SpecificationsHost Interface• Two Fibre Channel interfaces, 200MB\s each, 400 MB\s total.• External hub

Page 10 - Important safety information

91Rack EnclosureHeight: 5.22 inches (13.3cm)Width: 17.5 inches (44.5cm)Depth: 20 inches (50.8cm)Weight: 60 lbs (29.5kg) maximumWarrantyThree (3) years

Page 11 - Precautionary reminders

Appendix B Technical Specifications92Disk DrivesPower SupplyAC Power Supply InputTemperature• Operating Temperature: 5oC to 40oC• Temperature Storage:

Page 12 - Equipment rack precautions

93• Altitude Storage: -200 to 40,000 feetOperational ShockHalf sine shock: 3G half sine shock with a pulse duration of 11 milliseconds or less. No per

Page 13 - Important safety instructions

xiMultiple power cordsWarning! To avoid electrical shock, disconnect all AC power cords before accessing inside the system.Earth grounded socket-out

Page 14

Appendix B Technical Specifications94Immunity Testing: Light Industry CENELEC EN 50 082-1, 1997• Electrostatic Discharge CENELEC EN 61000-4-2, 1995• R

Page 15 - European Community Statement

Appendix CConfiguration Loop Diagram

Page 16

Appendix C Configuration Loop Diagram96Loop Diagram for a Single Enclosure System - Single Loop 345678910111213141516ExternalCircles denote disk drive

Page 17 - Introduction

97Loop Diagram for a Dual Enclosure System - Single Loop345678910111213141516ExternalCircles denote disk drives with drive ID shown.1819 2021222324252

Page 18

Appendix C Configuration Loop Diagram98Loop Diagram for a Single Enclosure System - Dual Loop345678910111213141516External Circles denote disk drives

Page 19

99Loop Diagram for a Dual Enclosure System - Dual Loop345678910111213141516ExternalCircles denote disk drives with drive ID shown.1819 202122232425262

Page 20 - Features

Appendix C Configuration Loop Diagram100

Page 21 - Cooling System

Appendix DUpgrading an Altos S700 JBOD Array to a RAID Array

Page 22 - I/O Option Modules

In this section the procedure for upgrading a Altos S700 Series Storage Array from a JBOD system to a RAID system is described. The equipment and part

Page 23 - Altos S700 RAID Controller

103Equipment and parts necessary for upgradeThe following is a list of the equipment and parts required for the upgrade from JBOD to RAID:• Anti-stati

Page 24 - Chapter 1 Introduction8

xiiEquipment rack precautionsFollow the rack manufacturer's safety and installation instructions for proper rack installation. The following add

Page 25

Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array1045 If you are upgrading to a dual RAID configuration then repeat steps 2 through 4 to i

Page 26 - Chapter 1 Introduction10

105Follow this procedure to install the Battery Backup Unit (BBU):1 Remove the ACM from the enclosure by loosening the two ACM screws and using the ha

Page 27 - Installation and Setup

Appendix D Upgrading an Altos S700 JBOD Array to a RAID Array106

Page 28

107IndexAadvanced cooling module, leds, 68advanced cooling modules, 5, 78,79air flow, 16ambient temperature, 16audience, viiBbattery

Page 29 - Safety Statements

108spin up sequence 58Ttechnical specifications, 90temperature, 16, 92terminal emulation 44Uunpacking, 15Vvibration, operational,

Page 30

xiiiImportant safety instructionsRead these instructions carefully. Save these instructions for future reference.1 Follow all warnings and instructio

Page 31 - Unpacking and Initial Setup

xivd If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are covered by the operat

Page 32 - Mechanical Loading

xvEuropean Community StatementThis equipment complies with the following European directives:EMC Directive 89/336/EEC and amending Directives 92/31/EE

Page 35 - (2Gb or 1Gb)

This Chapter introduces the Altos S700 Series. The main features of the Series are described along with a list of the models that are available.

Page 36

3IntroductionThe Altos S700 Series provides a highly flexible, high performance storage solution that evolves to meet your changing needs. Based on a

Page 37 - (Quad Loop)

Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such cha

Page 38 - 3 Replace the LS module

Chapter 1 Introduction4Features• Redundant data paths with dual-ported fibre drives and dual (200MB/s) fibre channel loops for a total of 400 MB/s.•

Page 39 - Configuration Rules

5Caution: Power supply cords shall have conductors with a cross-sectional area not less than 4mm2. This cross-sectional area corresponds to a minimum

Page 40 - Supported Host Bus Adapters

Chapter 1 Introduction6I/O Option ModulesThe two rear I/O option slots (A and B) can contain a range of different option modules. The LS module will

Page 41 - Supported Cables

7I/O Expansion Module- Optical/OpticalThis 2Gb FC expansion module has two SFF LC optical connectors. The top connector is the FC Loop Input port and

Page 42 - Optical Cables

Chapter 1 Introduction8Figure 1-1: Altos S700 Series Tower Model

Page 43 - JBOD Configurations

9Figure 1-2: Altos S700 Series Rack Model

Page 44

Chapter 1 Introduction10

Page 45 - Setting the Enclosure ID

Chapter 2 Installation and Setup

Page 46 - Enclosure ID

This Chapter describes the installation and set up of the Altos S700 Series. Important safety instructions are discussed along with the electrical, me

Page 47

13Safety StatementsThe following safety statements must be read before you install or operate the Altos S700 Series. For language translations of thes

Page 48 - Configurations

Preface viiAudience viiConventions Used In This User Guide viiEuropean Community Statement xvIntroduction 3Features 4Disk Drive Carrier 4Power Supplie

Page 49

Chapter 2 Installation and Setup14Warning: A possible shock hazard may exist in the area of the fan connection.Warning: Disconnect the power cords be

Page 50

15Unpacking and Initial SetupWhen you receive your system, visually inspect the exterior of the packaging for any signs of damage. If any damage is fo

Page 51 - Quad Loop Configuration

Chapter 2 Installation and Setup16Installing the System in an Equipment RackBefore installing the Altos S700 Series in an equipment rack, it is essen

Page 52

17least one other person when installing an enclosure. This is necessary to prevent personal injury and damage to the enclosure.

Page 53 - Connecting an AC Power Source

Chapter 2 Installation and Setup18Electrical ConsiderationsWhen installing the Altos S700 Series the following electrical considerations must be appl

Page 54 - Disk Drive Spin Up Sequence

19Setting Fibre Channel Loop Speed (2Gb or 1Gb)The Altos S700 Series can be operated with fibre channel loop speeds of either 2Gb (default) or 1Gb. Th

Page 55 - RAID Configurations

Chapter 2 Installation and Setup20Figure 2-1 Location of Jumpers on LS Module

Page 56

21Split Fibre Channel Loop Operation (Quad Loop)Note: Quad Loop is only available on JBOD systemsThe Altos S700 Series LS module allows for split FC L

Page 57

Chapter 2 Installation and Setup223 Replace the LS module.

Page 58

23Configuration RulesThese rules must be applied when implementing the Altos S700 Series configurations:• When daisy chaining, both 2Gb enclosures mus

Page 59 - I/O Circuit Board

ContentsivRAID Controller Status LEDs 46RAID Controller Configurations 47Setting the Enclosure ID 48Configurations 51Single RAID Controller Configurat

Page 60 - RS232 Serial Port

Chapter 2 Installation and Setup24Supported Host Bus AdaptersContact your sales person for a list of approved Host Bus Adapters.

Page 61 - RAID Controller Location

25Supported CablesWarning: Only the following APPROVED cables must be used with the Altos S700 Series enclosures.This section lists the cables that mu

Page 62 - RAID Controller Status LEDs

Chapter 2 Installation and Setup26Optical CablesThe following Fibre Channel Optical cables are available from Acer. Please contact your sales person

Page 63

Chapter 3JBOD Configurations

Page 64

This Chapter describes the procedure for connecting your Altos S700 Series JBOD system to a host computer(s). Detailed information on how to configure

Page 65

29Setting the Enclosure IDEach of the fourteen disk drive slots of the Altos S700 Series has a unique identifier assigned to it. This identifier is as

Page 66 - 0 1 2 3 4 5 6

Chapter 3 JBOD Configurations30Figure 3-1 Location of Enclosure ID SwitchThis enclosure ID switch can be set to 0 through 7.The graphic below shows

Page 67

31The fourteen disk drive slots (0 to 13), will be assigned an identifier based on the enclosure ID and the slot number as shown below.Enclosure ID Dr

Page 68

Chapter 3 JBOD Configurations32ConfigurationsThis section describes the procedures for cabling the main configurations of the Altos S700 Series JBOD.

Page 69

33JBOD ConfigurationsThere are two JBOD configurations covered in this Installation Guide:• Dual FC Loop mode (including how to daisy chain enclosures

Page 70

vDisk Drives 92Power Supply 92Temperature 92Humidity 92Altitude 92Operational Shock 93Operational Vibration 93Regulatory Agency Compliance 93Equipment

Page 71

Chapter 3 JBOD Configurations34Figure 3-2 Connecting dual FC Loop configuration to a hostSee Appendix C for Loop Diagram.To daisy chain enclosures

Page 72

35Figure 3-3 Daisy chaining dual FC Loop enclosuresSee Appendix C for Loop Diagram.Caution: When daisy chaining enclosures, you must ensure that eac

Page 73

Chapter 3 JBOD Configurations36This section describes the procedure for connecting the enclosure in quad loop mode. For this configuration there must

Page 74

37Connecting a Power SourceThe Altos S700 enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However,

Page 75 - System Monitoring

Chapter 3 JBOD Configurations38Disk Drive Spin Up SequenceAt power on, the LS module will perform its internal start up initialization routine. Then

Page 76

Chapter 4RAID Configurations

Page 77 - Overview

This chapter describes how to set up, configure and use the Altos S700 Series RAID Controller. Some general information about the RAID controller is a

Page 78 - LS Module

41Altos S700 Series RAID Controller IntroductionThe Altos S700 RAID Controller is a high performance controller, providing two host fibre channel and

Page 79 - Altos S700 Enclosure LEDs

Chapter 4 RAID Configurations42The controller, I/O, and ethernet circuit boards are assembled into a stack with the controller and ethernet boards mo

Page 80 - Description Color Indication

43RAID Controller Circuit BoardsThis section gives a brief description of the RAID controller circuit boards that are inside the RAID controller modul

Page 82

Chapter 4 RAID Configurations44The I/O circuit board has two SFF optical transceivers supporting shortwave multimode fibre on the host side and a 90-

Page 83 - Power OK

45RAID Controller LocationThe RAID controller is installed in the rear of the enclosure in the location shown in Figure 4-2.Figure 4-2 RAID Controll

Page 84

Chapter 4 RAID Configurations46RAID Controller Status LEDsThe RAID controller has 7 Status LEDs as shown above. describes what these LEDs signify.Co

Page 85 - RAID Controller LEDs

47RAID Controller ConfigurationsThis section describes how to cable the two standard RAID controller configurations: Single RAID Controller and Dual R

Page 86

Chapter 4 RAID Configurations48Setting the Enclosure IDEach of the fourteen disk drive slots of the Altos S700Altos S700 Series has a unique identifi

Page 87 - Removing Components

49The graphic below shows the slot number and location.The fourteen disk drive slots (0 to 13), will be assigned an identifier based on the enclosure

Page 88

Chapter 4 RAID Configurations50Slot 13 16 31 46 61 76 91 106 121Enclosure ID Drive Slot 0 1 2 3 4 5 67

Page 89 - Location of the Components

51ConfigurationsThis section shows how to connect the RAID enclosures to a host system(s). The procedure for daisy chaining the enclosures together is

Page 90 - Removing a Disk Drive Carrier

Chapter 4 RAID Configurations52Figure 4-5 Single RAID Controller to Host ConnectorDaisy Chaining a Single Controller EnclosureTo daisy chain the RA

Page 91 - Cam Lever

53Figure 4-6 Daisy Chaining Single Controller EnclosureCaution: When daisy chaining enclosures, you must ensure that each enclosure has a unique Enc

Page 92 - Removing an LS Module

viiPrefaceThis Installation Guide describes the installation and operation of the Altos S700 Series. The following products are covered: AS.S7001.001,

Page 93

Chapter 4 RAID Configurations54Dual RAID Controller ConfigurationIn this configuration two RAID Controllers are installed in the enclosures I/O slots

Page 94 - Removing a Power Supply

55Figure 4-7 Dual RAID Controller ConfigurationDaisy Chaining a Dual Controller EnclosureTo daisy chain the RAID enclosure to an expansion enclosure

Page 95 - Cooling Module

Chapter 4 RAID Configurations56Figure 4-8 Daisy Chaining a Dual Controller EnclosureCaution: When daisy chaining enclosures, you must ensure that e

Page 96 - Module/RAID Controller

57Connecting a Power SourceThe Altos S700 enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However,

Page 97 - Translations

Chapter 4 RAID Configurations58Disk Drive Spin Up SequenceAt power on, the LS module will perform its internal start up initialization routine. Then

Page 98 - Caution:

Chapter 5System Monitoring

Page 99

This Chapter describes the devices used to monitor the Altos S700 Series. The location of the monitoring LEDs and how to interpret them is described.

Page 100

61OverviewThe front mounted LS module is the main monitoring device of the Altos S700 Series. This module is complemented by status and fault LEDs, mo

Page 101

Chapter 5 System Monitoring62LS ModuleThe LS Module (Loop Resiliency and SES Module) provides monitoring and control for the Altos S700 Series. The m

Page 102

63Altos S700 Enclosure LEDsThe Altos S700 Series has six LEDs located on each of the front mounted LS Modules. These LEDs show the status of the enclo

Page 103

viiiNoticesFCC noticeThis device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules

Page 104

Chapter 5 System Monitoring64The table below shows the meaning of each of the LEDs, and how to interpret them.Note: If enabled, the audible alarm wil

Page 105 - Technical Specifications

65Disk Drive LEDsEach disk drive carrier has two LED indicators visible from the front of the Altos S700 enclosure. The green disk drive ready LED is

Page 106

Chapter 5 System Monitoring66Figure 5-2 Disk Drive Carrier LEDs18FDisk Drive Ready(Green)BiColor LED(Green/Amber)

Page 107 - Failure Notification

67Power Supply LEDsThe Altos S700 Series uses two AC power supplies. The AC power supplies provide 853W peak output power and 673W continuous output p

Page 108 - Temperature

Chapter 5 System Monitoring68Advanced Cooling Module (ACM) LEDsThe Altos S700 Series has two variable speed fans per advanced cooling module. Each of

Page 109 - Regulatory Agency Compliance

69RAID Controller LEDsThe RAID controller has 7 LEDs located and numbered as shown.Figure 5-5 RAID controller LEDsThe table below describes the LEDs

Page 110 - Electromagnetic Radiation

Chapter 5 System Monitoring70

Page 111 - Configuration Loop Diagram

Chapter 6Installing and Removing Components

Page 112 - Enclosure ID 0

This Chapter describes the procedures for installing and removing the replaceable components in the Altos S700 Series.Warning: The module handles are

Page 113 - Enclosure ID 1

73Location of the Components12120I0IDisk DrivesACMsPower SuppliesI/O Module/I/O Module/ModuleLSModuleRAID ControllerRAID Controller

Page 114

ixUse conditionsThis part complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause

Page 115

Chapter 6 Installing and Removing Components74Installing and Removing a Disk Drive CarrierThe disk drive carriers are located in the front of the enc

Page 116

75Figure 6-1 Disk Drive Carrier18FCam LeverPush locking tab in this direction to open

Page 117 - JBOD Array to a RAID Array

Chapter 6 Installing and Removing Components76Installing and Removing an LS ModuleThe LS Modules are located in the front of the enclosure. Follow th

Page 118

77Figure 6-2 LS Module012345Cam LeverPush locking tab in this direction to open

Page 119 - • Phillips head screw driver

Chapter 6 Installing and Removing Components78Installing and Removing a Power SupplyThe power supplies are located in the rear of the enclosure. Foll

Page 120

79Installing and Removing an Advanced Cooling ModuleThe advanced cooling modules are located in the rear of the enclosure. Follow these procedures to

Page 121

Chapter 6 Installing and Removing Components80Installing and Removing an I/O Module/RAID ControllerNote: In the following section, “I/O Module” is ta

Page 122

Appendix ASafety Statement Translations

Page 123

Appendix A Safety Statement Translations82Caution:This equipment is intended only for installation in a restricted access location.Caution: Dieses Ger

Page 124

83 Låt skivdrivenheter och strömtillförsel nå rumstemperatur innan strömförsörjningen slås på. Ennen kuin kytket virran hyllyyn sijoitettuihin levyase

Comments to this Manuals

No comments