To install SIMM modules:
1. Install the SIMMs in the sockets as shown starting with socket 1.
Refer to Appendix A, Assembly Drawings for socket locations. Be
sure the SIMM is fully seated and locked in the socket.
Although standard 32- or 36-bit 16MB or 64MB low-profile single-
sided 60ns EDO SIMMs can be used, DPT recommends that you
use DPT SM4050-16 or -64 ECC SIMMs for maximum data integrity.
2. To confirm that the SIMMs have been properly installed, use SMOR
to view the amount of cache memory reported when the
SmartRAID V controller is selected.